Project Committee meeting minutes are available to interested parties upon written request of the Manager of Standards. Attachments to minutes may or may not be included due to file size and/or because copyrighted intellectual property is included. Decisions to distribute attachments to the minutes will be made on a case by case basis and due to the size of the request may take longer to process.

Title, Purpose, and Scope

Safety Standard for Refrigeration Systems

Purpose:  This standard specifies safe design, construction, installation and operation of refrigeration systems.

Scope:
2.1 This standard establishes safeguards for life, limb, health, and property and prescribes safety requirements.

2.2 This standard applies to:
a.         the design, construction, test, installation, operation, and inspection of mechanical and absorption refrigeration systems, including heat pump systems used in stationary applications;
b.         modifications including replacement of parts or components if they are not identical in function and capacity; and
c.         substitutions of refrigerant having a different designation.

2.3 This standard does not apply to refrigeration systems using ammonia (R-717) as the refrigerant.

SPC 15.2P, Proposed standard authorized January 28, 2015. SSPC 15 is responsible for developing Standard 15.2P
Safety Standard for Air-conditioning and Heat Pump Systems in Residential Applications 

1. PURPOSE:  
This standard specifies safe design, installation, operation and maintenance of air-conditioning systems in residential applications.

2. SCOPE:
This standard establishes safeguards for life, limb, health and property and prescribes safety requirements.

This standard applies to the design, installation, operation and maintenance of mechanical air-conditioning and heat pump systems installed in stationary applications that include:

  1. one and two-family dwellings (single family detached, duplexes and townhomes), or
  2. multi-family structures with individual dwelling units, where each dwelling unit has its own heating and air-conditioning system, or
  3. outbuildings and pool houses located on the same private property as a one and two family dwelling

 

Committee Chair

Tip: This section automatically generated from site Configuration file.

Dennis Dorman

Webmaster

Tip: This section automatically generated from site Configuration file.

Gregory Scrivener

icon

Upcoming Society Conferences

2017 Annual Conference
June 24 - 28, 2017
Long Beach, California

Tip: You can put any type of content in the following section.

News